VITALink® 2-Hour Fire Resistive CIC Cable

https://smartbim-library-production.s3.amazonaws.com/manufacturers/7dd0a216-b007-4fcf-8fdd-ea9084602d12/products/0ab61760-f450-4ef9-a912-6273976077be/3bb67434-9954-4771-93e8-c072bbf19a4d/VITALink® 2-Hour Fire Resistive CIC Cable.png

Applications

Fire & Life Safety

Description


VITALink® Fire Resistive CIC cables can be installed either with or without conduit, depending on the application and code requirements. VITALink® CIC cables must be installed as the UL listed FHIT System 40A or FHIT7 System 40A and in accordance with the manufacturer’s installation instructions. These systems require use of specific hardware including conduit, couplings, pulling lubricant, pull boxes, and supports. In areas such as plenum airspace, VITALink® must be installed in conduit. VITALink® CIC cables are ideal for Emergency Voice/Alarm Communication Smoke and Fire Alarm Systems, Fireman’s Telephone and Area of Refuge Communication Systems and Visible Notification Appliances (VC05)

Features


- Withstands temperatures up to 1850°F & ensures 2 hour circuit protection

- Meets survivability requirements of NFPA 72 Level 2 and 3

- Listed for use in the United States (free air and conduit) & Canada (in conduit only)

- Sunlight resistant & suitable for use in wet locations

- Solutions for both plenum and riser installations

- No special tools or training required

- No termination kits, brass fittings, or stainless steel straps needed

- Installation requirements are outlined in manufacturer’s instruction guide

- All required hardware components are commercially available off-the-shelf

PropertyValue
Construction - Cabling3-8 Conductors
Construction - Conductor18-12 AWG Solid Bare Copper and 16-12 AWG Stranded Bare Copper
Construction - Drain WireStranded Bare Copper (Shielded constructions only)
Construction - InsulationLow Smoke, Zero Halogen Thermoset Fire-Roc®
Construction - JacketRed Non-Halogen Flame Retardant Polyolefin (Sequential footage markers every 2 feet) Other jacket colors & non-black jacket striping available upon request
Construction - ShieldCopper/Polyester Tape (Shielded constructions only)
Construction - TapeFlame Retardant Tape
CSA ListingsFAS 105 ST1 FT4
Performance StandardsANSI/UL 2196 2 Hour fire rating (See UL Fire Directory R27557) • ULC-S139/2196 Listed with Hose Stream Test for use in FHIT7 System 40A • UL 444 for Communication Cable; 300V / 105°C • NFPA 70, 72, 130, and 502 • Sunlight Resistant • For use in Wet Locations • NYC Electrical Advisory Board approval #54502, April 2017 • California State Fire Marshal Approved • RoHS Compliant
Volts300
UL ListingsUL Type FPLR-ST1, CMR-ST1, and CL3R-ST1 • UL 1424 • UL 13 • UL 444
Product CategoryCircuit Integrity, Power
RegionCanada
ApplicationsFire & Life Safety
Market ServedCommercial Infrastructure, Transit
Temperature105ºC