VITALink® MC Transit 2-Hour Fire Rated Power Cable

https://smartbim-library-production.s3.amazonaws.com/manufacturers/7dd0a216-b007-4fcf-8fdd-ea9084602d12/products/49eecfd0-2408-4827-924c-e263ff81f44e/c42918af-d0d7-406f-9c74-62db59a7213b/VITALink® RC90 Transit 2-Hour Fire Rated Power Cable.png

Applications

Fire & Life Safety

Description


VITALink® MC is a 600V 2-hour fire rated cable listed to UL 2196. It is specifically designed to meet both the electrical and fire-resistive cable requirements of NFPA 130 and NFPA 502 for emergency communications, emergency lighting & emergency ventilation. When installed per systems FHIT 120, 120A, and 60, plus the NEC, VITALink® MC meets code requirements for 2-hour Fire Rated Circuits, Electrical Circuit Integrity Systems, Survivability and Circuit Integrity. VITALink® MC Cables offer lowered cost, reliability and ease of installation advantages over MI cable and other methods of providing fire rated circuits. The equipment grounding copper armor is terminated with commercially available brass MC connectors and the cable connections are made without the need for splicing or use of special tools. Compared to Mineral Insulated (MI) cable, VITALink® MC is not exposed to costly field expenses in preparing cable ends, special panel penetrations, additional flexible terminations and the splicing of shorter lengths in longer runs. VITALink® MC is not susceptible to failures caused by moisture ingress through leaky seals or faulty storage. (VT01)

Features


- Up to 2-hour fire resistance

- Splice available

- Superior resistance to flame propagation

- Only conventional tools required to terminate

- Commercially available brass/stainless steel connectors

- Printed number coding allows for easy identification (ICEA Method 4)

- Labor savings on termination, installation, and handling

- Made in USA

- Superior impact & crush resistance (hazardous locations)

- Low smoke, low toxicity, halogen free design

- Welded armor forms an impervious barrier

- Sunlight resistant

- 90°C for wet locations

- Flexible

- Long continuous lengths available

- Multiple sizes and conductor counts available

- VFD cable design available

PropertyValue
Performance StandardsIEEE 1202/FT4 vertical flame test; ST1 limited smoke • Copper conductors to ASTM B8
Volts600
UL ListingsUL 2196 • UL 1569 • UL 2225
ApplicationsFire & Life Safety
Market ServedTransit
Temperature90ºC
Product CategoryPower, Circuit Integrity