Product Details
| Property | Value |
|---|---|
| Construction - Cabling | Required number of pairs cabled together |
| Construction - Circuit Identification | One leg of each pair is white. Up to 5 pairs, second legs are black, red, green, orange, or blue. Over 5 pairs, legs are white and black with printed pair number on each leg of each pair. |
| Volts | 600 |
| Performance Standards | Silicone rubber insulation ICEA S-19-81 • Class 1E IEEE 383-1974 and IEEE 323-1974 • IEEE 383-1974 70,000 BTU flame test as modified by NRC Reg. Guide 1.131 • ICEA T-29-520 210,000 BTU flame test • Single conductors IEEE 383-1974 |
| Construction - Pair Assembly | Two insulated and braided conductors twisted with a flexible strand, tin-coated copper drain wire, a helically applied aluminum/polyester laminated tape shield and an isolation tape |
| Construction - Overall Covering | Rockhidebraid* with high temperature finish |
| Construction - Insulation | Proprietary heat, moisture and radiation resistant silicone rubber |
| Construction - Fillers | As applicable |
| Construction - Conductor | Annealed, tin-coated copper, Class "B" strand (ASTM B8 & B33) |
| Construction - Covering | Glass braid with high temperature finish |
| Construction - Binder Tape | Helically applied polyester |
| Applications | Harsh Environment Power Control Instrumentation |
| Market Served | Nuclear |
| Temperature | 125ºC |
| Product Category | Instrumentation |
Product Resource download links.