Firewall® SR Thermocouple Extension Cable Multi-Shielded Pairs Without Overall Shield (Silicone Rubber)

https://smartbim-library-production.s3.amazonaws.com/manufacturers/7dd0a216-b007-4fcf-8fdd-ea9084602d12/products/dc5b95fb-1a8a-45ca-bf51-e77f132c76e8/e3250e29-0b09-4da0-8869-6e4b47c54d7b/Firewall® SR Instrumentation Cable Multi-Shielded Pairs Without Overall Shield .png

Applications

Harsh Environment Power Control Instrumentation

Description


Firewall® SR Thermocouple Extension Cable is a silicone rubber insulated construction specifically designed for high temperature applications within nuclear generating facilities. It is intended for use in harsh and demanding environments where temperature extremes preclude the use of standard cables. It may be installed in trays, ducts, conduits or in confined spaces such as equipment housings. Designed for use on circuits where shielding over individual pairs is required but additional overall shielding is not critical. (NU11_C)

Features


- Nuclear qualified with a minimum 40-year thermal life expectancy at 125°C

- Radiation resistant (up to 200 megarads)

- Extremely flame retardant

- Extremely flexible for installation ease

- Excellent circuit integrity during flame conditions

- Full traceability

- Easy strippability for termination ease

- All singles pass a wet dielectric (tank) test prior to braid covering to verify electrical integrity

- Shield to shield isolation system provided and verified by electrical testing

- All cables have printed sequential footage markers for improved inventory control

PropertyValue
Construction - Circuit IdentificationIndividual pair single conductors color coded to ANSI requirements by means of colored braids with printed pair numbers on both singles for pair identification
Volts600
Performance StandardsSilicone rubber insulation ICEA S-19-81 • Class 1E IEEE 383-1974 and IEEE 323-1974• IEEE 383-1974 70,000 BTU flame test as modified by NRC Reg. Guide 1.131 • ANSI standard MC 96.1 • ICEA T-29-520 210,000 BTU flame test • Single conductors IEEE 383-1974 para. 2.5.6 (ICEA S-19-81 Section 6.19.6) • 10 CFR 50 Appendix B
Construction - Pair AssemblyTwo insulated and braided conductors twisted with a flexible strand, tin-coated copper drain wire, a helically applied aluminum/polyester laminated tape shield and an isolation tape
Construction - Overall CoveringRockhide braid* with high temperature finish (colors to ANSI standards by type)
Construction - InsulationProprietary heat, moisture and radiation resistant silicone rubber
Construction - FillersAs applicable
Construction - ConductorSolid alloys per ANSI MC 96.1 (Extension Grade, standard limits of error)
Construction - CoveringGlass braid with high temperature finish
Product CategoryThermocouple
Construction - CablingRequired number of pairs cabled together
Construction - Binder TapeHelically applied polyester
ApplicationsHarsh Environment Power Control Instrumentation
Market ServedNuclear
Temperature125ºC